1# FT-04: Lighting
2
3<!-- Generated from field-tests/suite.json by tools/field_tests.py. Edit the JSON, not this file. -->
4
5**Category:** Light · **Time:** about 15 minutes · **Run it and see results:** [https://openckey.org/tests/test?id=FT-04](https://openckey.org/tests/test?id=FT-04)
6
7## What it checks
8
9A printed CKey reads in daylight, ordinary indoor light, dim light and under a reflection.
10
11## Why
12
13Low light adds noise and blur, warm light shifts colour, and glare washes out part of the code. The certification model includes noise and glare; this checks it against real rooms.
14
15## Test codes
16
17Print or open the sheet at [https://openckey.org/tests/sheet?id=FT-04](https://openckey.org/tests/sheet?id=FT-04). It is drawn by the CKey web SDK from the values below.
18
19| Code | Size | Version | Level | Layout | Style | Holds |
20|---|---|---|---|---|---|---|
21| A | 2.0 in | smallest that fits | M | standard | plain | `https://openckey.org/t/FT04-A` |
22
23## Set up
24
251. Print the test sheet at 100% scale; the code is 2.0 inches wide.
262. Keep the phone about 25 cm from the sheet with the flash off.
27
28## Steps
29
301. Try the code in each condition: outdoor daylight (not direct sun on the screen), ordinary indoor light, a dim room lit by one distant lamp, warm lamp light close by, and with a bright reflection crossing part of the code (glossy paper or a sheet protector under a lamp).
312. Allow up to 5 seconds in each.
323. Record whether it read, and optionally the light level from a light-meter app.
33
34## What to record
35
36- **Read within 5 seconds**, boolean, required. For each of: Daylight, Indoor, Dim, Warm lamp, Reflection.
37- **Light level, if measured** (lux), number, optional. For each of: Daylight, Indoor, Dim, Warm lamp, Reflection.
38
39Every report also records the device, operating system, reader and its version, and the printer or screen.
40
41## How to grade it
42
43- **Pass:** It read in daylight, indoor, dim and warm light.
44- **Partial:** It read in daylight and indoor light only.
45- **Fail:** It did not read in ordinary indoor light.
46
47## Report a result
48
49- On openckey.org: [https://openckey.org/tests/test?id=FT-04](https://openckey.org/tests/test?id=FT-04), with optional photos.
50- On GitHub: [open a field-test report](https://github.com/clearkeysolutions/ckey/issues/new?template=field-test-report.yml&title=%5BFT-04%5D+) and choose FT-04.
51
52Both are published together at [https://openckey.org/tests](https://openckey.org/tests) and as JSON at [https://openckey.org/api/field/results](https://openckey.org/api/field/results).